---
title: "6-Panel Benzodiazepine, Methamphetamine & Oxycodone Compact Drug Test Cup – 90 mL | BZO, COC, MET, OPI, OXY & THC"
url: "https://rapidscreening.surgescientific.com/products/6-panel-drug-test-cup-90ml-clia-waived-detecting-bzo-coc-met-opi-oxy-and-thc-as-low-as-0-99"
description: ".surge-6oxy-product { max-width: 1100px; margin: 0 auto; padding: 0; font-family: Arial, Helvetica, sans-serif; color: #0F2742; line-height: 1.5; } ."
---

# 6-Panel Benzodiazepine, Methamphetamine & Oxycodone Compact Drug Test Cup – 90 mL | BZO, COC, MET, OPI, OXY & THC

.surge-6oxy-product { max-width: 1100px; margin: 0 auto; padding: 0; font-family: Arial, Helvetica, sans-serif; color: #0F2742; line-height: 1.5; } .surge-6oxy-product * { box-sizing: border-box; } .surge-6oxy-product h2, .surge-6oxy-product h3, .surge-6oxy-product p { padding: 0 !important; } .surge-6oxy-product h2 { margin: 0 0 9px !important; line-height: 1.2; } .surge-6oxy-product h3 { margin: 22px 0 9px !important; line-height: 1.25; } .surge-6oxy-product p { margin: 0 0 9px !important; } .surge-6oxy-feature-grid { display: grid; grid-template-columns: repeat(4, minmax(0, 1fr)); gap: 10px; margin: 14px 0 18px; } .surge-6oxy-feature { background: #F4FAFA; border-top: 4px solid #0A7373; border-radius: 8px; padding: 14px; } .surge-6oxy-feature strong { display: block; color: #0A7373; font-size: 16px; line-height: 1.3; margin-bottom: 4px; } .surge-6oxy-banner { background: #0F2742; color: #FFFFFF; border-radius: 9px; padding: 19px; margin: 17px 0; } .surge-6oxy-banner strong { display: block; font-size: 21px; line-height: 1.3; margin-bottom: 4px; } .surge-6oxy-table-wrap { width: 100%; overflow-x: auto; margin: 10px 0 13px; } .surge-6oxy-drug-table, .surge-6oxy-spec-table { width: 100%; border-collapse: collapse; margin: 0; } .surge-6oxy-drug-table { min-width: 730px; border: 2px solid #0A7373; } .surge-6oxy-drug-table th { background: #0A7373; color: #FFFFFF; padding: 12px 10px; text-align: left; font-size: 14px; border-right: 1px solid #FFFFFF; } .surge-6oxy-drug-table th:first-child { text-align: center; } .surge-6oxy-drug-table td { padding: 10px 12px; vertical-align: middle; border-bottom: 1px solid #D7E7E7; } .surge-6oxy-drug-table tr:nth-child(even), .surge-6oxy-spec-table tr:nth-child(even) { background: #F4FAFA; } .surge-6oxy-strip { display: inline-block; min-width: 145px; padding: 5px 8px; color: #FFFFFF; text-align: center; font-size: 8px; font-weight: bold; line-height: 1.25; } .surge-6oxy-note { background: #FFF7EF; border-left: 5px solid #BF6000; padding: 14px 16px; margin: 13px 0 18px; } .surge-6oxy-note strong { color: #BF6000; } .surge-6oxy-info { background: #EAF7F6; border: 1px solid #BFDCD9; border-left: 5px solid #0A7373; padding: 14px 16px; margin: 13px 0 18px; } .surge-6oxy-info strong { color: #0A7373; } .surge-6oxy-result { padding: 14px 16px; border: 1px solid #D7E7E7; margin: 0; } .surge-6oxy-result:first-child { border-radius: 8px 8px 0 0; } .surge-6oxy-result:last-child { border-radius: 0 0 8px 8px; } .surge-6oxy-result strong { display: block; font-size: 18px; margin-bottom: 3px; } .surge-6oxy-spec-table { min-width: 520px; border: 1px solid #D7E7E7; } .surge-6oxy-spec-table td { padding: 10px 12px; border-bottom: 1px solid #D7E7E7; } .surge-6oxy-regulatory { display: grid; grid-template-columns: 1fr 1fr; gap: 10px; margin: 13px 0 18px; } .surge-6oxy-regulatory-box { background: #F4FAFA; border-left: 5px solid #0A7373; padding: 15px; border-radius: 7px; } .surge-6oxy-regulatory-box strong { display: block; color: #0A7373; font-size: 18px; margin-bottom: 4px; } .surge-6oxy-faq { border: 1px solid #D7E7E7; border-radius: 8px; overflow: hidden; margin: 12px 0 18px; } .surge-6oxy-faq-item { padding: 15px 16px; border-bottom: 1px solid #D7E7E7; } .surge-6oxy-faq-item:last-child { border-bottom: 0; } .surge-6oxy-faq-item:nth-child(even) { background: #F4FAFA; } .surge-6oxy-faq-item strong { display: block; color: #0A7373; font-size: 17px; margin-bottom: 4px; } .surge-6oxy-cta { background: linear-gradient(135deg, #0F2742 0%, #0A7373 100%); color: #FFFFFF; text-align: center; border-radius: 10px; padding: 24px 20px; margin: 20px 0 13px; } .surge-6oxy-cta strong { display: block; font-size: 24px; line-height: 1.3; margin-bottom: 7px; } .surge-6oxy-cta-button { display: inline-block; background: #BF6000; color: #FFFFFF; padding: 10px 23px; border-radius: 5px; font-weight: bold; margin-top: 12px; } @media screen and (max-width: 850px) { .surge-6oxy-feature-grid { grid-template-columns: 1fr 1fr; } } @media screen and (max-width: 600px) { .surge-6oxy-feature-grid, .surge-6oxy-regulatory { grid-template-columns: 1fr; } .surge-6oxy-product h2 { font-size: 27px !important; } .surge-6oxy-product h3 { font-size: 22px !important; } } 6 DRUG PANELS • OPI/2000 &amp; OXY • COMPACT 90 mL CUP 6-Panel Benzodiazepine, Methamphetamine &amp; Oxycodone Compact Drug Test Cup Comprehensive preliminary urine drug screening in one compact, self-contained 90 mL cup. This compact urine drug test cup screens for benzodiazepines, cocaine, methamphetamine, high-cutoff opiates, oxycodone and marijuana. The separate OPI/2000 and OXY panels provide targeted screening for traditional opiates and oxycodone, which may not be detected equally by a standard opiate panel alone. Specimen collection, temperature verification and preliminary screening take place in one convenient device. The secure no-drip twist lid, built-in temperature strip and easy-to-read result panel help reduce spills, specimen transfers and unnecessary handling. Results are available in approximately five minutes. Product Highlights Six-Drug Screening Screens for BZO, COC, MET, OPI, OXY and THC in one compact test cup. Dedicated Oxycodone Panel Separately screens for oxycodone at the manufacturer-listed 100 ng/mL cutoff. High-Cutoff Opiate Panel Screens morphine and related opiates using the listed OPI/2000 cutoff. Dedicated MET Panel Screens for methamphetamine at the listed 1,000 ng/mL cutoff. Results in Minutes Provides clear preliminary results in approximately five minutes. One-Step Testing Collection and screening take place in one fully self-contained device. Compact 90 mL Capacity Provides practical specimen capacity in an easy-to-handle format. Leak-Resistant Lid Secure no-drip twist closure helps minimize spills, leaks and accidental opening. Built-In Temperature Strip Supports prompt verification of specimen temperature after collection. Easy Result Interpretation Clearly marked test and control regions simplify preliminary result reading. Manufacturer-Stated Accuracy Manufacturer information reports up to 99% accuracy when used as directed. Same-Day Shipping Eligible orders placed within the processing window ship the same business day. Six Drug Panels with Dedicated OPI/2000, OXY and MET Screening A practical solution for medical offices, occupational health clinics, treatment facilities, collection sites, probation programs, correctional settings and authorized workplace screening. Drug Panels and Cutoff Levels Review the six drug categories and manufacturer-listed screening cutoff levels included in this configuration. TEST STRIP TESTED DRUG ESTIMATED DETECTION TIME / CUTOFF BZO BZO BZO BZO BZO BZO BZO BZO BZO BZO Benzodiazepines 1–2 Days • 300 ng/mL COC COC COC COC COC COC COC COC COC COC Cocaine 2–4 Days • 300 ng/mL MET MET MET MET MET MET MET MET MET MET Methamphetamine 2–4 Days • 1,000 ng/mL OPI OPI OPI OPI OPI OPI OPI OPI OPI OPI Morphine / Opiates 2–3 Days • 2,000 ng/mL OXY OXY OXY OXY OXY OXY OXY OXY OXY OXY Oxycodone 1–3 Days • 100 ng/mL THC THC THC THC THC THC THC THC THC THC Marijuana 5+ Days • 50 ng/mL Please Note: Detection times vary from person to person and may be affected by dosage, frequency of use, metabolism, hydration, body composition and specimen concentration. Refer to the manufacturer’s package insert for exact cutoff levels and interpretation instructions. Expanded Opioid Screening: This configuration uses an OPI/2000 panel for morphine and related opiates and includes a separate OXY panel at 100 ng/mL. The dedicated oxycodone panel provides targeted screening that a traditional opiate panel may not provide with equal sensitivity. How to Use the 6-Panel BZO, MET &amp; OXY Compact Drug Test Cup Understanding the 6-Panel BZO, MET &amp; OXY Compact Drug Test Cup Results Product Dimensions and Specifications 6-Panel Compact Drug Test Cup Drug Panels BZO, COC, MET, OPI, OXY and THC Opiate Cutoff OPI/2000 Oxycodone Cutoff OXY/100 Testing Format Integrated urine collection and screening cup Result Time Approximately 5 minutes Capacity 90 mL Height 2.53 inches Bottom Width 2.12 inches Lid Width 2.75 inches Approximate Weight 0.14 lb CLIA Waived and FDA 510(k) Cleared This 6-panel compact drug test cup is CLIA Waived and FDA 510(k) Cleared for the intended uses listed in the manufacturer’s labeling. It may be used in eligible point-of-care settings operating under a CLIA Certificate of Waiver, with no other moderate- or high-complexity laboratory certification required. What CLIA Waived Means The test is considered simple to perform and may be used by eligible sites holding a CLIA Certificate of Waiver when the manufacturer’s instructions are followed exactly. What FDA 510(k) Cleared Means The device has completed the applicable FDA premarket-clearance process for the intended uses listed in its authorized labeling. This compact test cup may be suitable for physician offices, occupational health clinics, treatment and recovery facilities, collection sites, law-enforcement settings, probation and correctional programs, staffing agencies and qualifying workplace-screening programs. Regulatory Notice: FDA clearance and CLIA-waived status are separate designations. Follow the manufacturer’s instructions and all applicable federal, state and local testing requirements. Frequently Asked Questions 1. What drugs does this 6-panel urine test cup screen for? It screens for benzodiazepines, cocaine, methamphetamine, opiates, oxycodone and marijuana. 2. What does OPI/2000 mean? OPI/2000 indicates that the opiate panel uses a 2,000 ng/mL screening cutoff for morphine and related opiates. 3. Why is oxycodone tested separately? Oxycodone is a semi-synthetic opioid that may not be detected with equal sensitivity by a standard opiate panel. This cup includes a separate OXY panel at 100 ng/mL. 4. How quickly are results available? Preliminary results are available in approximately five minutes. Results should not be interpreted after eight minutes or outside the manufacturer’s stated reading window. 5. Is this cup CLIA Waived and FDA 510(k) Cleared? Yes, according to the supplied manufacturer information for this configuration. It may be used in eligible waived settings operating under a CLIA Certificate of Waiver. Six Drug Panels. Dedicated OXY and MET Screening. Compact 90 mL Design. Simplify preliminary urine drug screening with a self-contained test cup designed for secure collection, fast results and easy visual interpretation. Order 6-Panel Compact Test Cups Today

## Offer

- Price: $2.30

- Availability: In stock

## Collection

- [CLIA Waived Drug Test Cups](https://rapidscreening.surgescientific.com/collections/clia-waived-drug-test-cups.md)

## Links

- [HTML product page](https://rapidscreening.surgescientific.com/products/6-panel-drug-test-cup-90ml-clia-waived-detecting-bzo-coc-met-opi-oxy-and-thc-as-low-as-0-99)
- [All collections](https://rapidscreening.surgescientific.com/collections.md)
